TROUBLESHOOTING AND REPAIR
19
Before troubleshooting the system, the following inspection should be performed.
1. Inspection of Power Source Voltage
Check the voltage of the power source.
Single phase 115 volts (60Hz)
Check the operation and condition of the fuse or circuit breaker in the power source.
2. Inspection of Air Filters
Remove the air filters and check the element. If the element is dirty, wash it as described in the OPERATION
MANUAL supplied with the unit.
3. Inspection of Drain Tank
Be sure tank is fully drained.
The following chart is provided as a guide for categorized problem remedies. Detailed information is con-
tained in the OPERATION MANUAL supplied with the unit.
4. Self-Diagnostic Codes
Self-Diagnostic codes will be displayed on the control board under the following conditions:
DF When the evaporator antifreeze thermistor disengages the compressor.
TF When the drain tank switch shuts off the unit (full tank LED flashes).
AS Unit disengages the compressor when the water level safety switch has activated.