TROUBLESHOOTING
Office Pro 60 Self-Diagnostic Codes
Self-Diagnostic Codes will be displayed on the Control Board under
the following conditions:
TANK
FULL
SET POINT
F
C
ROOM TEMP
AM
PM
SET TEMP CLOCK/TIMER
FAN ON/OFF
COOL ON/OFF PROGRAM
Office Pro 60
SET
START TIME
END TIME
SET CLOCK
RUN
HRS MIN
Check the following points before calling a qualified technician.
SYMPTOM POSSIBLE CAUSE REMEDY
Unit does not operate Ground fault breaker tripped Reset breaker
Drain tank is full Empty the drain tank
(FULL TANK LED will be
flashing)
Insufficient cooling Dirty/blocked air filters Clean air filters
Air inlet/outlet blocked Clear air inlet/outlet
Improper temperature setting Set to desired position
If symptoms persist after the above actions have been taken, turn the
unit off, disconnect the power cord plug and contact your MovinCool
reseller.
dF When the evaporator freezestat
disengages the compressor.
FL When the drain tank switch shuts
off the unit (FULL TANK LED
flashes).
AS When unit disengages the com-
pressor while the condensate
pump is discharging water.
HP When the high pressure switch
disengages the compressor.
LO Lowest temperature set point.