23
A
B
DISCHARGE HOSE
DRAIN PUMP
REMOVABLE PANEL
DRAIN PUMP
RESERVOIR
OPERATION (cont.)
Drain Pump Kit (Optional)
A drain pump kit (CPK-7) is available to allow continuous operation and
to eliminate the need for a drain tank.
When the water collects to level
(A) in the pump reservoir, the drain
pump begins to operate and
discharges the water.
NOTE: The compressor will not operate while the drain pump is
discharging water. The info display area will show AU code while
the pump is discharging the water. When the pump has discharged
the water from the reservoir the AU code will no longer be dis-
played.
When the water level drops below level (B), the drain pump stops,
and the compressor will restart.
NOTE: If the Fan Mode Control DIP Switch (see pg. 16) is set to the
STOP position, the entire unit (including fan operation) will turn off
when the drain pump is discharging water.
NOTE: Before a drain pump can be installed, a pump attachment
plate must be attached to the base of the pump. This pump plate
must then be secured to the base of the unit. Do not install the
condensate pump without the pump plate.