TROUBLESHOOTING AND REPAIR
21
Before troubleshooting the system, the following inspection should be performed.
1. Inspection of Power Source Voltage
Check the voltage of the power source.
Single phase 230 volts (60Hz)
Check the operation and condition of the fuse or circuit breaker in the power source.
2. Inspection of Air Filters
Remove the air filters and check the element. If the element is dirty, wash it as described in the OPERATION
MANUAL supplied with the unit.
3. Inspection of Drain Tank (If equipped)
Be sure tank is fully drained.
The following chart is provided as a guide for categorized problem remedies. Detailed information is con-
tained in the OPERATION MANUAL supplied with the unit.
4. Self-Diagnostic Codes
Self-Diagnostic codes will be displayed on the control
board under the following conditions:
dF When the evaporator anti-freeze thermistor
disengages the compressor.
FL When the drain tank switch shuts off the unit
(full tank LED flashes).
AS When unit disengages the compressor while
the condensate pump is discharging water.
HP When the high pressure switch disengages
the compressor.
TANK
FULL
SET POINT
F
C
ROOM TEMP
AM
PM
SET TEMP CLOCK/TIMER
FAN ON/OFF
COOL ON/OFF PROGRAM
Office Pro 60
SET
START TIME
END TIME
SET CLOCK
RUN
HRS MIN
OP60 Control Panel
Page view 28
1 2 ... 24 25 26 27 28 29 30 31 32 33 34 ... 55 56

Comments to this Manuals

No comments